MEASUREMENT DATA | |
---|---|
Carbon dioxide (CO2), carbon monoxide (CO), Oxygen (O2) | |
PRESSURE RANGE | |
Measurement | Ambient |
0 – 420 barg (6100 psig) (pressure range options) | |
MEASURING PRINCIPLE | |
CO2 | Nondispersive infrared spectroscopy (NDIR) |
CO, O2 | Electrochemical |
Humidity | Capacitive (only using B-SECURUS) or via dew point sensor (as option) |
LOWEST DETECTION LIMIT | |
CO2 | 0 ppm (parts per million) |
CO | 0 ppm |
O2 | 0.1 % |
MEASUREMENT VALUES | |
CO2 | 0 … 5000 ppm |
CO | 0 … 30 ppm |
O2 | 0 … 50% |
MEASUREMENT ACCURANCY | |
CO2 | ± 10 % FS (full scale) |
CO | ± 5 % FS |
O2 | ± 2 % FS |
FURTHER TECHNICAL DATA | |
Alarms | Alarm when one or more limit values is exceeded |
Operating voltage | 12 V DC |
Power consumption | Max. 36 W |
Dimension W × H × D [mm] (w/o connection and accessories) |
Mobile: 250 × 305 × 135 |
SYSTEM TEST/CALIBRATION | |
Visual inspection and leak test | once a month |
Functions check ¹ | at least every three month |
System check ² | once a year |
Calibration | CO2 sensor before commissioning, after replacing the sensor; dew point sensor: every two years |
¹ Including test with test gas; corresponding kit containing test gas cylinders and pressure reducer (flow meter) available from BAUER KOMPRESSOREN.
² The system check includes replacing the electrochemical sensors (CO and O2 ).